Welcome to Accuthermo Technology Corp.
-
A Total Thermal Solution Provider
Part Number
(1) Size
|
(2) Input |
(3) Output 1 |
(4) Output 2 |
(5) Option |
(6) Power Source |
VT4830
48mm x 48mm (1/16DIN)
VT7230
72mm x 72mm
VT4930
48mm x 96mm (H) (1/8DIN)
VT9630
96mm x 96mm (1/4DIN) |
T: Thermocouple
D: PT100
L: 0~20mA
M: 4~20mA
O: 0~10Vdc
V: 1~5Vdc |
R: Relay
P: SSR
L: 0~20mA
M: 4~20mA
O: 0~10Vdc
V: 1~5Vdc |
N: None
R: Relay
P: SSR
L: 0~20mA
M: 4~20mA
O: 0~10Vdc
V: 1~5Vdc |
N: None
C: RS-485
R: PV/SV retransmission
P: Remo Setpoint |
A: 90~264Vac 50/60Hz
D: 24Vdc |
Optional :
•Output 2 for cooling control.
•Process value or setpoint value Retransmission
•Master & Slaver transmission
•RS-485 communication(MODBUS RTU)
•Power supply : DC/AC 24V
Applications :
•Indicator / Controller for Temperature, Humidity, Pressure, Air-Conditioning, Gas Detector, DC Current/Voltage, ...etc.
•With retransmission, RS485
Specifications
Input
|
Thermocouple: J. K. T. E. B. R. S. N.C |
RTD: DIN PT-100; JIS PT-100 |
Linear: 4~20mA; 0~50mV; 1~5V; 0~10V… |
Accuracy
|
T/C±1℃; RTD±0.2℃; Linear±3μV |
Sampling Time
|
0.25 sec. |
Control
|
Proportional band: 0.0~300.0% F.S |
Integral time: 0~3600 sec. |
Derivative time : 0~900 sec. |
Hysteresis: 0.0~200.0 or 0.0~2000 |
Cycle Time: 0~100 sec. |
Cycle Time
(0~100)
|
Relay 15 sec. |
Pulsed voltage to drive SSR: 1sec. |
Continuous current (Voltage): 0 sec. |
Output
|
Relay contact output: 10A/ 240 VAC (Resistive load) |
Pulsed Voltage Output to Drive SSR: DC 0/24V
(Resistive 250Ωmin.) |
Current Output: 4~20mA; (Resistive 600 Ωmax.) |
Continuous Voltage Output: 0~50mV; 1~5V; 0~10V.....
(Resistive 600 Ωmin.) |
General
|
Rated Voltage: AC 90~264V 50 / 60HZ; DC 24V |
Ambient Temperature: 0~50℃ |
Ambient Humidity: 0~90 % |
Consumption: Less than 5VA |
Input
Type
|
TEMPERATURE RANGE ( ℃ )
|
TEMPERATURE RANGE ( ℉ )
|
J
|
-50℃ ~ 1000℃
|
-58℉~ 1832℉
|
K
|
-50℃ ~ 1370℃
|
-58℉~ 2498℉
|
T
|
-270℃ ~ 400℃
|
-454℉~ 752℉
|
E
|
-50℃ ~ 750℃
|
-58℉~ 1382℉
|
B
|
0℃ ~ 1800℃
|
32℉~ 3272℉
|
R
|
0℃ ~ 1750℃
|
32℉~ 3182℉
|
S
|
0℃ ~ 1750℃
|
32℉~ 3182℉
|
N
|
-50℃ ~ 1300℃
|
-58℉~ 2372℉
|
C
|
-50℃ ~ 1800℃
|
-58℉~ 3272℉
|
DPT
|
-200℃ ~ 850℃
|
-328℉~ 1652℉
|
JPT
|
-200℃ ~ 650℃
|
-328℉~ 1202℉
|
LINE
|
-1999 ~ 9999
|
Alarm Function
Process High Alarm
|
Process Low Alarm
|
Deviation High Alarm
|
Deviation Low Alarm
|
Band High Alarm
|
Band Low Alarm
|
Time Signal Output
|
PV High Alarm with Delay Time
|
PV Low Alarm with Delay Time
|
Dimension
Wiring Diagram
Download
Data sheet
|