- Welcome to Accuthermo Technology Corp.
- A Total Thermal Solution Provider
Communication & I/O
Category Name: RS485 I/O Module Ethernet I/O Module
-
- EDAM9052 (16-ch Digital input/source type output module)
- •Ethernet 10/100 Based-T communication
•Support protocol Modbus/TCP,TCP/IP,UDP,ICMP,ARP
•Support dry/wet contact input
•Support counter/frequency input
•Support isolated input/output channels
•Provides pulsed/delay output mode
•Provides source type digital output
•Built-in TVS/ESD protection
•Fully photo-isolation 3750Vrms
-
- EDAM9051 (14-ch Digital I/O with 2-ch counter module)
- •Ethernet 10/100 Based-T communication
•Support protocol Modbus/TCP,TCP/IP,UDP,ICMP,ARP
•Support dry/wet contact input
•Support counter/frequency input
•Support isolated input/output channels
•Provides pulsed/delay output mode
•Built-in TVS/ESD protection
•Built-in 2-ch high speed counters
•Fully photo-isolation 3750Vrms
-
- EDAM9017 (8-ch Analog input module)
- •Ethernet 10/100 Based-T communication
•Support protocol Modbus/TCP,TCP/IP,UDP,ICMP,ARP
•Support ±V,±mV,mA analog input
•Support isolated input channels
•Provides two digital output(open collector)
•Built-in TVS/ESD protection
•Wide supply voltages(10~30V)
•Fully photo-isolation 3750Vrms
-
- EDAM9015 (7-ch RTD input module)
- •Ethernet 10/100 Based-T communication
•Support protocol Modbus/TCP,TCP/IP,UDP,ICMP,ARP
•Burn-out auto detection
•Support Pt100,Pt1000,Ni518 RTD types
•Support isplated input channels
•Built-in TVS/ESD protection
•Wide supply voltages(10~30V)
•Fully photo-isolation 3750Vrms
-
- EDAM-8060D (4-ch isolated digital input and 4-ch relay output module with LED)
- •Automatic data flow control on RS-485
•Baute rate : up to 115.2K(bps)
•Programmable host watch dog timer for host failure protection
•4-ch isolated digital input with common source and 4-ch relay output
•Support EDAM ASCII format protocol(default)
•Fully photo-isolation 3750Vrms
-
- EDAM-8018 (8-ch Analog / Thermal couple temperature input module)
- •Automatic data flow control on RS-485
•Baute rate : up to 115.2K(bps)
•Alarm function with high / low alarm output
•Programmable host watch dog timer for host failure protection
•6 differential and 2 single-ended or 8 differential analog input
•Support thermocouple (J, K, T, E, R, S, B, N, C) type
•Support 60 samples/second (12bit) fast sampling rate
•Thermocouple : J , K , T , E , R , S , B , N , C type
•Fully photo-isolation 3750Vrms
-
- EDAM-8012D (A/D digital input and open collector output module)
- •Automatic data flow control on RS-485
•Baute rate : up to 115.2K(bps)
•Alarm function with high / low alarm output
•Programmable host watch dog timer for host failure protection
•1-ch analog input with differential input for voltage and current measurement
•1-ch digital input / event counter, 2-ch open collector digital output
•Support EDAM ASCII format protocol
•Fully photo-isolation 3750Vrms
-
- EDAM-8531 (Isolated USB to RS-422 / RS-485(TX,RX,RTS,CTS) converter)
- •USB 1.1 Compliant
•Automatic direction flow control on RS-485
•Full-Duplex RS-422 support
•RTS & CTS handshake signals support for RS-422
•Minimum 3000 VDC isolation protection
•Transient suppression on RS-485 data lines
•Automatically switch USB signal to RS-422 or RS-485 (jumperless)
•Auto switching baud rate up to 115.2 Kbps
•Reserved space for termination resistors
•Power and activity indicator for troubleshooting
•Driver support for Windows 95/98/ME/2000/XP, Linux
•Power requirement: USB bus power
•Mounts easily on DIN-rail or panel
-
- EDAM-8530 (Isolated USB to RS-232 / RS-422 / RS-485 converter)
- •USB 1.1 Compliant
•Automatic direction flow control on RS-485
•Full-duplex RS-232/RS-422 support
•RS-232 RTS & CTS signals support
•Minimum 3000 VDC isolation protection
•Transient suppression on RS-485 data lines
•Automatically switch USB signal to RS-232/RS-422 or RS-485
(jumperless)
•Auto switching baud rate up to 115.2 Kbps
•Reserved space for termination resistors
•Power and activity indicator for troubleshooting
•Driver support for Windows 95/98/ME/2000/XP, Linux
•Power requirement: USB bus power
•Mounts easily on DIN-rail or panel
-
- EDAM-8520A (Isolated RS-232 to RS-422 / RS-485 converter)
- •Automatic direction flow control on RS-485
•Auto switching for RS-232 to RS-422 or RS-485(jumperless)
•Auto switching baud rate up to 115.2 Kbps
•Minimum 3000 VDC isolation protection
•Transient suppression on RS-485 data lines
•Networking up to 4000 feet
•Reserved space for termination resistors
•Power and data flow LED indicator for troubleshooting
•Power requirement: +10 to +30 VDC
•Mounts easily on DIN-rail or panel
-
- EDAM-8510 (Isolated RS-422 / RS-485 repeater)
- •Automatic internal RS-422/485 bus supervision
•No external flow control signals required for RS-485
•Minimum 3000 VDC isolation protection
•Transient suppression on RS-485 data lines
•Supported baud rate up to 115.2 Kbps
•Reach distance up to 4000 feet (1200 m)
•Reserved space for termination resistors
•Power and data flow LED indicator for troubleshooting
•Power requirement : +10 to +30 VDC
•Mounts easily on DIN-rail or panel