- Welcome to Accuthermo Technology Corp.
- A Total Thermal Solution Provider
Product
-
- MPC Microprocessor Based Module Type PID Controller
- •DIN rail mounting, Compact size.
•Universal input/output selectable.
•10 samples per second.
•4 independent LEVEL PID.
•Ramp/Soak program (16 segments profile with loop / link / jump function).
•Soft-Start function.
•Digital communication with MODBUS RTU Protocol.
•All parameters can be easily configured by PC with URC-1020 interface cable or EzPro hand held programmer.
•PV bias / PV ratio correction.
•Output 2 for cooling control.
-
- SD 660 Microprocessor Indicator
- Standard :
•0.8"Large LED Display.
•T/C, RTD, Linear Input selection.
•Universal Power supply : 90-264V AC, 50/60Hz. DC / AC 24V is also available for option.
•3 Alarm output. (note 1)
•Standby and Latch mode can be combined with 8 different alarm functions.
•Retransmission or RS-485 communication(MODBUS RTU) is available for option.
Note1: 2nd and 3rd Alarm are available for option.
-
- Solid State Relay
- •Control signals of 4~32 Vdc, 90~250 Vac or resistance potentionmeter
•25 amps or 40 amps load switching
•250Vac & 480 Vac line voltage ratings
•Zero Voltage Turn-on
•Zero Current Turn-off
•Built-in Snubber Circuit Protection
•"LED" Indicating Control Signal Status
•Low Leakage
•DIN Rail & Panel Mount Heat Sinks Available
•Low Input current ( 7 mA (Max) @ 32 Vdc )
•CE Approval
-
- FTX700 H-Bridge Amplifier for TEC Temperature Controller Systems
- •High efficiency bi-directional control for heating and cooling applications
•Solid-state bridge control
•High-power FET H-bridge operation
•Designed for use with Accuthermo TE temperature controllers
•Ideal for high-power applications – 600W max power output
-
- EzPro Handheld Programmer
- •For ISC、ISD、ISA、IST-D、IST-H、IST-P、MPC
-
- EDAM9052 (16-ch Digital input/source type output module)
- •Ethernet 10/100 Based-T communication
•Support protocol Modbus/TCP,TCP/IP,UDP,ICMP,ARP
•Support dry/wet contact input
•Support counter/frequency input
•Support isolated input/output channels
•Provides pulsed/delay output mode
•Provides source type digital output
•Built-in TVS/ESD protection
•Fully photo-isolation 3750Vrms
-
- EDAM9051 (14-ch Digital I/O with 2-ch counter module)
- •Ethernet 10/100 Based-T communication
•Support protocol Modbus/TCP,TCP/IP,UDP,ICMP,ARP
•Support dry/wet contact input
•Support counter/frequency input
•Support isolated input/output channels
•Provides pulsed/delay output mode
•Built-in TVS/ESD protection
•Built-in 2-ch high speed counters
•Fully photo-isolation 3750Vrms
-
- EDAM9017 (8-ch Analog input module)
- •Ethernet 10/100 Based-T communication
•Support protocol Modbus/TCP,TCP/IP,UDP,ICMP,ARP
•Support ±V,±mV,mA analog input
•Support isolated input channels
•Provides two digital output(open collector)
•Built-in TVS/ESD protection
•Wide supply voltages(10~30V)
•Fully photo-isolation 3750Vrms
-
- EDAM9015 (7-ch RTD input module)
- •Ethernet 10/100 Based-T communication
•Support protocol Modbus/TCP,TCP/IP,UDP,ICMP,ARP
•Burn-out auto detection
•Support Pt100,Pt1000,Ni518 RTD types
•Support isplated input channels
•Built-in TVS/ESD protection
•Wide supply voltages(10~30V)
•Fully photo-isolation 3750Vrms
-
- EDAM-8060D (4-ch isolated digital input and 4-ch relay output module with LED)
- •Automatic data flow control on RS-485
•Baute rate : up to 115.2K(bps)
•Programmable host watch dog timer for host failure protection
•4-ch isolated digital input with common source and 4-ch relay output
•Support EDAM ASCII format protocol(default)
•Fully photo-isolation 3750Vrms
-
- EDAM-8018 (8-ch Analog / Thermal couple temperature input module)
- •Automatic data flow control on RS-485
•Baute rate : up to 115.2K(bps)
•Alarm function with high / low alarm output
•Programmable host watch dog timer for host failure protection
•6 differential and 2 single-ended or 8 differential analog input
•Support thermocouple (J, K, T, E, R, S, B, N, C) type
•Support 60 samples/second (12bit) fast sampling rate
•Thermocouple : J , K , T , E , R , S , B , N , C type
•Fully photo-isolation 3750Vrms
-
- EDAM-8012D (A/D digital input and open collector output module)
- •Automatic data flow control on RS-485
•Baute rate : up to 115.2K(bps)
•Alarm function with high / low alarm output
•Programmable host watch dog timer for host failure protection
•1-ch analog input with differential input for voltage and current measurement
•1-ch digital input / event counter, 2-ch open collector digital output
•Support EDAM ASCII format protocol
•Fully photo-isolation 3750Vrms
-
- EDAM-8531 (Isolated USB to RS-422 / RS-485(TX,RX,RTS,CTS) converter)
- •USB 1.1 Compliant
•Automatic direction flow control on RS-485
•Full-Duplex RS-422 support
•RTS & CTS handshake signals support for RS-422
•Minimum 3000 VDC isolation protection
•Transient suppression on RS-485 data lines
•Automatically switch USB signal to RS-422 or RS-485 (jumperless)
•Auto switching baud rate up to 115.2 Kbps
•Reserved space for termination resistors
•Power and activity indicator for troubleshooting
•Driver support for Windows 95/98/ME/2000/XP, Linux
•Power requirement: USB bus power
•Mounts easily on DIN-rail or panel
-
- EDAM-8530 (Isolated USB to RS-232 / RS-422 / RS-485 converter)
- •USB 1.1 Compliant
•Automatic direction flow control on RS-485
•Full-duplex RS-232/RS-422 support
•RS-232 RTS & CTS signals support
•Minimum 3000 VDC isolation protection
•Transient suppression on RS-485 data lines
•Automatically switch USB signal to RS-232/RS-422 or RS-485
(jumperless)
•Auto switching baud rate up to 115.2 Kbps
•Reserved space for termination resistors
•Power and activity indicator for troubleshooting
•Driver support for Windows 95/98/ME/2000/XP, Linux
•Power requirement: USB bus power
•Mounts easily on DIN-rail or panel
-
- EDAM-8520A (Isolated RS-232 to RS-422 / RS-485 converter)
- •Automatic direction flow control on RS-485
•Auto switching for RS-232 to RS-422 or RS-485(jumperless)
•Auto switching baud rate up to 115.2 Kbps
•Minimum 3000 VDC isolation protection
•Transient suppression on RS-485 data lines
•Networking up to 4000 feet
•Reserved space for termination resistors
•Power and data flow LED indicator for troubleshooting
•Power requirement: +10 to +30 VDC
•Mounts easily on DIN-rail or panel
-
- EDAM-8510 (Isolated RS-422 / RS-485 repeater)
- •Automatic internal RS-422/485 bus supervision
•No external flow control signals required for RS-485
•Minimum 3000 VDC isolation protection
•Transient suppression on RS-485 data lines
•Supported baud rate up to 115.2 Kbps
•Reach distance up to 4000 feet (1200 m)
•Reserved space for termination resistors
•Power and data flow LED indicator for troubleshooting
•Power requirement : +10 to +30 VDC
•Mounts easily on DIN-rail or panel
-
- FSTS R TYPE Temperature Sensor
- •Suitable for the temperature sensing of rubber, Teflon, silicone and metal heating rollers, conveyors, motor spindles, etc
•Temperature sensing surface has excellent abrasion resistance and a long lifespan
•Compact, simple installation
•Temperature rise is fast and stable
•Resistant against acid, base and various solvents
•Applicable for heating rollers of any size
•Application Example: Roller Equipment、Power Equipment、Conveying Equipment、Surface Temperature Sensing
-
- FSTS B Type Temperature Sensor
- •Suitable for the abnormal temperature detection on the pipe-shape objects in power plants, cogeneration plants, chemical plants, and semiconductor manufacturing plants
•Applicable Temperature Range: -30°C~250°C
•Accuracy: DINIEC751 class A or B
•Material is UL certified and complies with UL94HB rating
•Superconductive temperature sensing, stable and fast response speed
•Simple installation and resistance against severe environment and chemicals
•Application Example: Chemical Plant、Power Plant、Cogeneration Plant、Pipe-shape Equipment、Surface Temperature Sensing
-
- FSTS MS TYPE Temperature Sensor
- •Suitable for the temperature sensing in refrigerators, freezers, communication machine rooms, and indoor environment
•Can be attached on the surface made of PE, PP, ABS, PET and various metals
•Can be attached repeatedly
•Passed MSDS certification
•Superconductive, fast, stable and accurate
•Application Example: Refrigerator (Freezer) for Medical Products、Communication Machine Room、Central Control Room、Communication Environment Control Room、Indoor Temperature Sensing for Fire Alarm
-
- FSTS M / M1 TYPE Temperature Sensor
- •The best abnormal temperature detector for your equipment
•The best solution for surface temperature sensing
•Applicable temperature range:-30°C~250°C
•Accuracy: DINIEC751 class A or B
•The material has been certified by UL and complies with UL94HB fire-resistance rating
•Fast and accurate temperature sensing; 100% IP68 water proof
•It can be attached on the surface of the object to be sensed with the advantages of simple installation, resistance against severe environment and chemicals
•Can be securely attached on glass, metal, plastics, etc
•Application Example: Electrical Power Equipment、Solar Energy Equipment、Electronic Equipment、Power Equipment、Surface Temperature Sensing
-
- FSTS S Type Temperature Sensor
- •The best abnormal temperature detector for your equipment
•The best solution for surface temperature sensing
•Applicable temperature range:-30°C~250°C
•Accuracy: DINIEC751 class A or B
•The material has been certified by UL and complies with UL94HB fire-resistance rating
•Fast and accurate temperature sensing; 100% IP68 water proof
•It can be attached on the surface of the object to be sensed with the advantages of simple installation, resistance against severe environment and chemicals
•Can be securely attached on glass, metal, plastics, etc
•Application Example: Power Plant、Cogeneration Plant、Chemical Plant、Large Pipe Diameter、Large Area、Surface Temperature Sensing
-
- Thermocouple & RTD Sensor
- Thermocouple :
The basic theory of the thermocouple effect is found from a consideration of the electrical and thermal transport properties of different metals. A measurement junction (this junction is formed of different metal) is exposed to the environment whose temperature is to be measured. The other "reference" junction (known as cold junction) are held at common. The "seeback voltage" then is proportional to the difference between junction temperatures. Certain standard configurations of thermocouples using specific metals (or alloys of metals) have been adoped, each type has its particular features. Such as range, linearity inertness to hostile environment sensitivity, and so on, and is chosen for specific applications accordingly.