home » product » Controllers & Indicators » Controllers » VD Series Low Cost Temperature Controllers
Controllers & Indicators » Controllers
•T/C, RTD, Linear Input selection.
•P, PD, ON/OFF control mode selection.
•Universal Power supply : 90-264V AC, 50/60Hz. DC 24V is also available for option.
•3 Alarm output. (note 1)
•Standby and Latch mode can be combined with 8 different alarm functions.
•Retransmission or RS-485 communication(MODBUS RTU) is available for option.
Part Number
 

(1) Size

(2) Input (3) Output 1 (4) Alarm (5) Option (6) Power Source
 VD2600
 48mm x 48mm (1/16DIN)
 VD2601
 72mm x 72mm 
 VD2603
 96mm x 48mm (H) (1/8DIN)
 VD2604
 96mm x 96mm (1/4 DIN)
 T: Thermocouple
 D: PT100
 L: 0~20mA
 M: 4~20mA
 O: 0~10Vdc
 V: 1~5Vdc
 R: Relay
 P: SSR
 L: 0~20mA
 M: 4~20mA
 O: 0~10Vdc
 V: 1~5Vdc

 1: 1 x Alarm
 2: 2 x Alarm
 3: 3 x Alarm

 N: None
 C: RS-485
 R: PV/SV retransmission
 A: 90~264Vac 50/60Hz
 D: 24Vdc
 

 
Note1: 2nd and 3rd Alarm are available for option.
 
Applications :
 Indicator / Controller for Temperature, Humidity, Pressure,Air-Conditioning, Gas Detector, DC Current/Voltage, ...etc.
With retransmission, RS485
 
 

 
Specifications
 
Input
Thermocouple: J. K. T. E. B. R. S. N.C
RTD: DIN PT-100; JIS PT-100
Linear: 4~20mA; 0~50mV; 1~5V; 0~10V…
Accuracy
T/C±1℃; RTD±0.2℃; Linear±3μV
Sampling Time
0.25 sec.
Control
P Control: Proportional Band: 0.0~300.0% F.S
PD Control: Proportional Band: 0.0~300.0% F.S
Derivative Time : 0~900 sec.
ON / OFF Control: Hysteresis 0~2000
Cycle Time
(0~100)
Relay 15 sec.
Current Output (SSR) 1 sec.
Continuous Current (Voltage): 0 sec.
 Output
Relay Contact Output: 10A/ 240 VAC (Resistive load)
Pulsed Voltage Output to Drive SSR: DC 0/24V
(Resistive 250Ωmin.)
Current Output: 4~20mA; (Resistive 600 Ωmax.)
Continuous Voltage Output: 0~50mV; 1~5V; 0~10V.....
(Resistive 600 Ωmin.)
General
Rated Voltage: AC 90~264V
Ambient Temperature: 0~50℃
Ambient Humidity: 0~90 %
Consumption: Less than 3VA
 

 
Input
 
Type
TEMPERATURE RANGE ( ℃ )
TEMPERATURE RANGE ( ℉ )
J
-50℃ ~ 1000℃
-58℉~ 1832℉
K
-50℃ ~ 1370℃
-58℉~ 2498℉
T
-270℃ ~ 400℃
-454℉~ 752℉
E
-50℃ ~ 750℃
-58℉~ 1382℉
B
0℃ ~ 1800℃
32℉~ 3272℉
R
0℃ ~ 1750℃
32℉~ 3182℉
S
0℃ ~ 1750℃
32℉~ 3182℉
N
-50℃ ~ 1300℃
-58℉~ 2372℉
C
-50℃ ~ 1800℃
-58℉~ 3272℉
DPT
-200℃ ~ 850℃
-328℉~ 1652℉
JPT
-200℃ ~ 650℃
-328℉~ 1202℉
LINE
-1999 ~ 9999
 

 
Alarm Function
 
PV High Alarm
PV Low Alarm
Deviation High Alarm
Deviation Low Alarm
Band High Alarm
Band Low Alarm
PV High Alarm with
Delay Time
PV Low Alarm with
Delay Time
 

 
Dimension
 
 

 
Wiring Diagram
 
 

 
Download
 
     Data sheet