Welcome to Accuthermo Technology Corp.
-
A Total Thermal Solution Provider
Part Number
The unit will come standard with PT100, -200~600°C, you can change the input Type/Rang using the free software " " with the configuration cable URC-1020, or you can contact us for non-standard Input/Rang setting.
(1) Model No.
|
(2) Input Signal(PV1) / Maximum Range
|
(3) Input Signal(PV2) / Maximum Range |
(4) Output 1 |
(5) Output 2 |
(6) URC-1020 Interface Cable |
ISD |
J: -50 to 1000 °C (-58 to 1832°F)
K: -50 to 1370 °C (-58 to 2498°F)
T: -270 to 400 °C (-454 to 752°F)
E: -50 to 700°C (-58 to 1292°F)
B: 0 to 1750 °C (32 to 3182°F)
R: -50 to 1750 °C (-58 to 3182°F)
S: -50 to 1750 °C (-58 to 3182°F)
N: -50 to 1300 °C (-58 to 2372°F)
C: -50 to 1800 °C (-58 to 3272°F)
Pt100: -200 to 600° C (-328 to 1112°F)
mV: -60mVto 60mV
Voltage: -10 to 10Vdc
Current: 0 to 24mAdc |
M: 4~20mA
V: 0~10Vdc |
M: 4~20mA
V: 0~10Vdc
C: RS-485 |
N: No
Y: Yes |
The Din Rail converter is user configurable with the software and interface cable URC-1020 or handheld programmer.
The is user-friendly software. The latest release version can be download free from website.
Interface cable consist of interface converter and USB plug. It can be purchased separately from supplier. During configuration the converter can work alone without connecting to a power source.
The unit will come standard with PT100, -200~600°C, you can change the input Type/Rang using the free software " " with the configuration cable URC-1020, or you can contact us for non-standard Input/Rang setting.
Specification
Input |
Thermocouple (T/C) : industry standard thermocouple types J, K, T, E, B, R, S, N, C (ITS-90). |
Pt100: Excitation 180uA. 2 or 3 wire connection (ITS-90 α =0.00385). |
Voltage: -60mVdc to 60mVdc or –10Vdc to 10Vdc. |
Current : 0-24mAdc |
Accuracy |
Refer to Table 1 Input Signal |
A/D Resolution |
16 bits |
Input Sampling Rate |
<200ms |
Power Supply |
DC 24V |
Output |
Current Output: 0/4~20mA( Resistive load 600Ω max.) |
Continuous Voltage Output: 0~50mV; 0~10V…( Resistive load 600Ω min.) |
Output Resolution |
0.6 μ A(15 bits) |
Output Response Time |
<200ms |
Common Mode Rejection Ratio(CMRR) |
>80dB |
Electromagnetic Compatibility (EMC) |
En 50081-2, En 50082-2 |
Galvanic isolation |
3.75 KV. between input and output |
Operating Temperature |
-40 to 85 ° C |
Humidity |
0 to 90% RH |
Dimension |
75mm(W)x87mm(H)x18.5mm(D) |
Table 1 Input Signal
Input signal |
Maximum Range |
Accuracy |
Thermocouple J |
-50 to 1000 ° C (-58 to 1832 ° F ) |
± 1 ° C |
Thermocouple K |
-50 to 1370 ° C (-58 to 2498 ° F ) |
± 1 ° C |
Thermocouple T |
-270 to 400 ° C (-454 to 752 ° F ) |
± 1 ° C |
Thermocouple E |
-50 to 700 ° C (-58 to 1292 ° F ) |
± 1 ° C |
Thermocouple B |
0 to 1750 ° C (32 to 3182 ° F ) |
± 2 ° C (Note1) |
Thermocouple R |
-50 to 1750 ° C (-58 to 3182 ° F ) |
± 2 ° C |
Thermocouple S |
-50 to 1750 ° C (-58 to 3182 ° F ) |
± 2 ° C |
Thermocouple N |
-50 to 1300 ° C (-58 to 2372 ° F ) |
± 2 ° C |
Thermocouple C |
-50 to 1800 ° C (-58 to 3272 ° F ) |
± 2 ° C |
Pt100 |
-200 to 600 ° C (-328 to 1112 ° F ) |
± 0.2 ° C |
mV |
-60mVto 60mV |
± 0.01m V |
Voltage (Note2) |
-10 to 10Vdc |
± 1m V |
Current (Note2) |
0 to 24mAdc |
± 10μA |
Note 1 : Accuracy is not guaranteed between 0 and 400°C (0 and 752°F) for type B.
Note 2 : The internal DIP switch should be set.
Dimension
Wiring Diagram
Block Diagram
Download
|
|
ISWinC100625 |
Data sheet |
Accessories
|
|
EzPro Handheld Programmer
|
URC-1020 Interface Cable |
|